Stopwatches are the default mode for timers. The mode can be changed to the Countdown mode. Learn more in the Timers topic.
Countdowns count time down from a set value; when zero is reached, a trigger can fire an alert pop-up and a command.
The countdown timer has an hourglass icon (
) in the upper right corner of the pool object.
Besides the "ElapsedTime" property mentioned in the Timers topic (link above), the Countdown also has a "RemainingTime" read-only property.
Countdown Settings
The countdowns have more settings besides the common settings described in the Timer topic.
Countdown
-
Countdown Time:
Sets the duration time of the countdown. The maximum possible countdown time is limited to 14 days. The calculator sets the duration time in seconds, minutes, hours, and days. -
Countdown Alert Type:
The alert type defines what should happen when the countdown reaches zero. There are four options:-
None:
Nothing happens when the timer runs out, except it stops. -
Pop-Up:
A pop-up appears with the text set in the Alert Text setting (see below). The pop-up appears for as long as the Alert Duration is set (see below). -
Command:
The timer executes the command set in the Alert Command setting (see below). -
Command & Pop-Up:
The pop-up appears, and the command is triggered.
-
None:
Alert
-
Alert Duration:
Defines how long the pop-up should be displayed when the Countdown Timer reaches zero. An alert duration of zero seconds means the pop-up stays until confirmed. The countdown alert type needs to include "Pop-Up" for this setting to be active. -
Alert Range:
The countdown alert range defines where the pop-up appears.-
Local:
The alert pop-up appears on the stations with users logged in using the same user profile as the one who started the countdown. -
All Stations:
The alert pop-up appears on all stations in the session. Countdowns with this setting have a small G icon (
) in the upper right corner of the pool object to indicate that it is a global countdown.
The pop-up has a confirmation button to close the alert (before the duration closes it). Confirm only confirms for the station where it is tapped. Confirm All Stations confirm the alert on all stations.
-
Local:
-
Alert Command:
When the countdown reaches zero, the command is executed on the GlobalMaster/IdleMaster station or the Standalone station. The Countdown Alert Type needs to include "Command" for this setting to be active. -
Alert Text:
The defined text of this setting is displayed in the alert pop-up when the countdown reaches zero. The countdown alert type needs to include "Pop-Up" for this setting to be active.