• grandMA3 User Manual
  • grandMA3 Quick Manual consoles
  • grandMA3 Quick Manual processing
  • grandMA3 Quick Manual nodes
  • grandMA3 Quick Manual DIN-Rail
    • Intended Use
    • Safety
    • Support
    • Transport
    • Limitations
    • Installation
    • Quick Start
    • Maintenance
    • Disposal
    • Technical Data
    • Conformity
  • grandMA3 Quick Manual onPC solutions
  • Release Notes
Select different version
 
Hint:
New help version
The help version you selected belongs to an older software version. You may want to view the latest help version.
Version 1.1

Installation

Table of contents of this topic

Hint:
Install the grandMA3 xPort Node DIN-Rail on the rail following DIN EN 60715. 
Important:
Install the grandMA3 xPort Node DIN-Rail horizontally so that the input terminal is located at the bottom and the DMX terminal on top. 
 Warning:
In order for the device to dissipate heat, comply with a minimum distance of 30 mm (approx. 2 inches) above and beneath the grandMA3 xPort Node DIN-Rail. 
 
  1.  Install the grandMA3 xPort Node DIN-Rail onto the rail.
Place the grandMA3 xPort Node DIN-Rail on the rail

 

Snap it into place
  1. Build the xPort Node DIN-Rail into the switchboard. 

 

Connections

Connect with electrical grid

-or- 

Connect via PoE

 

Power  

Connector

MC 1.5/ 3-ST1-5.08

Rigid cables

0.75 mm² - 1.5 mm² (18-16 AWG)

Flexible cables

0.75 mm² - 1.5 mm² (18-16 AWG)
Wire end sleeves are permitted.

Wire stripping length

7 mm 

Tightening torque

0.22 Nm - 0.25 Nm

DMX  

Connector

FK-MC 0.5/ 3-ST-2.5

Rigid cables

0.14 mm² - 0.5 mm² (26-20 AWG)

Flexible cables

0.14 mm² - 0.5 mm² (26-20 AWG)
Wire end sleeves are permitted. 

Wire stripping length

8 mm

 


Select different version