- grandMA3 User Manual
- grandMA3 Quick Start Guide
- grandMA3 Quick Manual consoles
- grandMA3 Quick Manual processing units
- grandMA3 Quick Manual Nodes
- grandMA3 Quick Manual Nodes DIN-Rail
- grandMA3 Quick Manual onPC command wing XT
- grandMA3 Quick Manual onPC command wing
- grandMA3 Quick Manual onPC fader wing
- grandMA3 Quick Manual onPC rack-unit
- grandMA3 Quick Manual viz-key
- grandMA3 Quick Manual I/O Nodes
- Intended Use
- Safety
- Support
- Transport
- Limitations
- Installation
- Quick Start
- Maintenance
- Disposal
- Technical Data
- Conformity
- Release Notes
Hint:
New help version
The help version you selected belongs to an older software version. You may want to view the latest help version.
New help version
The help version you selected belongs to an older software version. You may want to view the latest help version.
Version 1.7
Installation
Hint:
The grandMA3 I/O Node can be connected with the power cable. Only the grandMA3 I/O Nodes DIN-Rail need to be installed on the rail following DIN EN 60715 and the instructions below.
The grandMA3 I/O Node can be connected with the power cable. Only the grandMA3 I/O Nodes DIN-Rail need to be installed on the rail following DIN EN 60715 and the instructions below.
Important:
Install the grandMA3 I/O Node DIN-Rail horizontally so that the input terminal is located at the bottom.
Install the grandMA3 I/O Node DIN-Rail horizontally so that the input terminal is located at the bottom.
Warning:
In order for the device to dissipate heat, comply with a minimum distance of 30 mm (approx. 2 inches) above and beneath the grandMA3 I/O Node DIN-Rail.
In order for the device to dissipate heat, comply with a minimum distance of 30 mm (approx. 2 inches) above and beneath the grandMA3 I/O Node DIN-Rail.
- Install the grandMA3 I/O Node DIN-Rail onto the rail.
- Build the I/O Node DIN-Rail into the switchboard.
Connections
-or-
Power | |
---|---|
Connector |
MC 1.5/ 3-ST1-5.08 |
Rigid cables |
0.75 mm² - 1.5 mm² (18-16 AWG) |
Flexible cables |
0.75 mm² - 1.5 mm² (18-16 AWG) |
Wire stripping length |
7 mm |
Tightening torque |
0.22 Nm - 0.25 Nm |
MIDI & LTC | |
---|---|
Connector |
FK-MC 0.5/ 3-ST-2.5 |
Rigid cables |
0.14 mm² - 0.5 mm² (26-20 AWG) |
Flexible cables |
0.14 mm² - 0.5 mm² (26-20 AWG) |
Wire stripping length |
8 mm |
DC Remote | |
---|---|
Connector |
FK-MC 0.5/ 7-ST-2.5 |
Rigid cables |
0.14 mm² - 0.5 mm² (26-20 AWG) |
Flexible cables |
0.14 mm² - 0.5 mm² (26-20 AWG) |
Wire stripping length |
8 mm |